Wall insulation & vapour barrier
Batt insulation is only as good as its installation — fitted without gaps or compression, and closed in with a vapour barrier that is sealed at every lap, outlet and penetration. That is the standard we install to.
- Insulation
- Batts sized to the wall cavity
- Vapour barrier
- 6-mil poly, sealed laps & boxes
- Warranty
- Lifetime labour warranty
Where most batt installations fail
Fibreglass and mineral wool batts perform well when they completely fill the cavity. Batts that are compressed behind wiring, cut short around boxes or left with gaps at the top plate lose a meaningful share of their R-value.
The vapour barrier is the other half of the assembly. In Alberta it sits on the warm side of the wall, and it has to be continuous: laps sealed with acoustical sealant over framing, and outlets and fixtures wrapped so warm, moist air cannot reach the cold side of the wall. A torn or unsealed barrier is how condensation gets into walls.
Projects we insulate
Renovations
Exterior walls opened up during a remodel — insulated and sealed before drywall.
Additions
New walls insulated and vapour-barriered to match the rest of the envelope.
Basement developments
Framed basement walls, including the rim joist, ready for inspection.
Garages & bonus spaces
Walls between heated and unheated space where comfort and air quality matter.
A complete, inspection-ready assembly
We coordinate with your contractor or schedule around your own timeline.
- 01
Batts fitted to cavity
Split around wiring, cut tight to boxes and plates — no gaps, no compression.
- 02
6-mil poly vapour barrier
Continuous on the warm side, with laps over framing sealed with acoustical sealant.
- 03
Sealed penetrations
Electrical boxes and fixtures wrapped or fitted with vapour-barrier boxes and sealed.
- 04
Ready for drywall
Clean site and photo documentation so you or your inspector can verify the work.
Typical batt sizes
- 2×4 walls: R-12 to R-14 batts
- 2×6 walls: R-20 to R-24 batts
- Final specification confirmed against your permit and plans
Walls & Vapour Barrier: common questions
What R-value should my walls be?
It depends on wall depth and your project’s requirements. 2×4 walls typically take R-12 to R-14 batts and 2×6 walls R-20 to R-24. For permitted work we match the specification on your plans.
Which side does the vapour barrier go on?
In Alberta’s climate the polyethylene vapour barrier goes on the warm (interior) side of the insulation, directly behind the drywall.
Why does the poly need to be sealed?
Gaps and unsealed laps let warm, moist air into the wall where it can condense on cold surfaces. Sealing laps with acoustical sealant over framing and sealing around boxes keeps the barrier continuous.
Can you insulate walls without removing the drywall?
Batt and poly insulation is installed in open walls. If your walls are closed, we will tell you honestly what is and is not practical during the assessment.
Do I need a permit or inspection?
If the insulation is part of a renovation, addition or basement development that requires a permit, an insulation and vapour barrier inspection is typically part of it. We schedule our work so the assembly is ready before drywall.
Do you work with my contractor?
Yes. We regularly fit into renovation schedules and coordinate directly with general contractors and homeowners.